- UMM AL QUWAIN U.A.E
Series A cast-iron
To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
Ex-d, Ex-de
Frame size 63 ÷ 315
ATEX category 1M2, 2G
Group I (mine), IIB, IIC
Temperature class T3, T4, T5, T6
Protection IP55 ÷ IP66
Power 0.05 ÷ 240 kW
Three-phase 1 or 2 speed
Single-phase (frame size 63÷100)
Ventilation IC410, IC411, IC416, IC418
Series F aluminium
IEC 60079-0, IEC 60079-1, IEC 60079-7
Ex-d, Ex-de
Frame size 56 ÷ 80
ATEX category 2D, 2G, 2GD
Group IIB, IIC
Temperature class T4, T5, T6
To Norms IEC 61241-0, IEC 61241-1
A21 – tD
Protection IP55, IP65
Maximum surface temperature [°C] T125, T85, T70
To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
Power 0.06 ÷ 1.5 kW
Three-phase 1 or 2 speed
Single-phase
Ventilated, unventilated
PAD mounting
Series D, H, cast-iron
To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
Ex-d, Ex-de
Frame size 63 ÷ 315
ATEX category 2G
Group IIB, IIC
Temperature class T3, T4
Protection IP55 ÷ IP65
Power 0.05 ÷ 132 kW
Three-phase 1 or 2 speed
A.C. or D.C. disk brake
Ventilation IC410, IC411, IC416, IC418
Series A cast-iron
To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
Ex-d, Ex-de
Frame size 63 ÷ 315
ATEX category 2G
Group IIB, IIC
Temperature class T3, T4
Protection IP55 ÷ IP66
Power 0.05 ÷ 240 kW
Three-phase
Ventilation IC410, IC411, IC416, IC418
Series F aluminium
IEC 60079-0, IEC 60079-1, IEC 60079-7
Ex-d, Ex-de
Frame size 56 ÷ 80
ATEX category 2D, 2G, 2GD
Group IIB, IIC
Temperature class T4, T5, T6
To Norms IEC 61241-0, IEC 61241-1
A21 – tD
Protection IP55, IP65
Maximum surface temperature [°C] T125, T85, T70
To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
Power 0.06 ÷ 1.5 kW
Three-phase 1 or 2 speed
Single-phase
Self cooled (IC411); forced cooling (IC416); unventilated (IC418)
PAD mounting
Electrical variants
Special voltage and frequency
Bimetallic thermal protection (NC, NO), thermistor (PTC), platinum resistor (PT100)
Single-phase with permanent capacitor
Single-phase with centrifugal switch
Mechanical variants
Protection IP56, IP65, IP66
Special flanges and shafts
Without terminal box (loose leads)
Terminal box on side
Uni-directional bearings, locked bearings or special bearings
SPM probe (vibrations measurement)
Heaters
Series AN
Norms IEC-EN 60079-0:2009, 60079-15:2010, 60079-31:2009
Ex-nA
Frame size (cast-iron) 63 ÷ 315
certificated by Notified Body
ATEX category 3G
Group II
Temperature class T3 (max 170 °C)
Protection IP55
Power 0.05 ÷ 200 kW
Three-phase 1 or 2 speed
Ventilation IC410, IC411, IC416, IC418
Available IE2
Series AD, AQ
To Norms IEC-EN 60079-0:2009, 60079-15:2010, 60079-31:2009
Ex tb, Ex tc
Frame size (cast-iron) 63 ÷ 315 certificated by Notified Body
ATEX category 2D, 3D
Group IIIB, IIIC
Protection IP65 ÷ IP55
Maximum surface temperature [°C] T135, T100, T85
Power 0.05 ÷ 200 kW
Three-phase 1 or 2 speed
Single-phase (frame size 63÷100)
Ventilation IC410, IC411, IC416, IC418
Available with brake
Available for Gas + Dust (Series AQ)